Co-Design & Develop
Take a working idea to a medical-grade product, with the design history file built as we go rather than reconstructed at the end. Nine technical disciplines under one roof and one ISO 13485 system.
What Co-Design & Develop Covers

Industrial Design
How the device is held, read and operated, worked out with the people who will use it and tested against IEC 62366-1 rather than assumed.
See how it works
Mechanical Engineering
The physical device: the parts, how they fit and how they are made, with biocompatibility under ISO 10993 in view from the first material choice.
See how it works
Electronics
Electronics designed to reduce the risk of failing safety and electromagnetic testing. Insulation, leakage and emissions are set against IEC 60601-1 at schematic stage, not after a failed test report.
See how it works
Embedded Firmware & BLE
The firmware inside the device, written under the IEC 62304 lifecycle. Battery life, wireless reliability and update security are design decisions, not later fixes.
See how it works
Mobile / Web / Cloud App
The phone, browser and server software the device talks to, developed under IEC 62304 alongside the hardware so the two are verified together.
See how it works
AI / ML
Models built on clinically labelled data, with the dataset, the training record and the performance evidence assembled the way a regulator will ask to see them.
See how it works
Verification & Validation
Proof that the device meets its requirements and works in real hands. Every protocol traces back to the risk file held under ISO 14971.
See how it works
India Regulatory Dossier
The Indian submission assembled while the device is being designed, so the dossier is a collation at the end rather than a rewrite.
See how it works
International Regulatory
What the US and the EU ask for, prepared from the design file you already hold rather than rebuilt market by market.
See how it worksHow the Work Runs
- 01
Write the Inputs
Needs turned into requirements that can be tested, each with a number.
- 02
Design in Stages
Iterations with a design review at each stage, and the decisions recorded.
- 03
Verify
Each output tested against the requirement it answers.
- 04
Hand Over
Design outputs released, with the design history file built as the work went.
Where This Fits in the Five Stages
Devices We Have Worked On
We name the type of device, not the client. Client work stays confidential. See every device type.
- Pulsed lavage irrigation system for orthopaedic surgery
- Battery-powered bone drill with its docking station
- Suturing device for wound closure
- Manual wound debridement instrument set
- Bipolar coagulation instrument for neurosurgery
- Blood and fluid warmer, in two flow ranges
Run under an ISO 13485:2016 quality system certified by TÜV SÜD, certificate 99 400 00046. What it covers.
Who Usually Starts Here
Tools for This
Three free tools that run in your browser and send us nothing: a readiness check, an intended use builder and your likely class and licence.