What the US and the EU ask for, prepared from the design file you already hold rather than rebuilt market by market.

When to use it

When International Regulatory Work Is the Right Step

When a device is headed for the US or the EU. Each market sets its own class and route, so the plan is made per market, from the same design file.

  • Enter the US Market

    A 510(k) premarket notification against a predicate device, or a De Novo or PMA route where no predicate fits.

  • Enter the EU Market

    Technical documentation under EU MDR 2017/745, for a notified body review or for self-declaration where the class allows it.

  • Choose the Markets and Their Order

    A regulatory strategy that compares class, route and evidence in each market before you commit.

How International Regulatory Work Runs

  1. Step 1

    Classify in Each Market

    The class of the device in every market you are aiming at.

  2. Step 2

    Choose the Route

    510(k), De Novo or PMA in the US; the notified body route in the EU.

  3. Step 3

    Compile

    The technical documentation or submission, from the design file.

  4. Step 4

    Support the Review

    Answers to the regulator's or the notified body's questions.

What you get

What You Bring and What You Get

You Bring

  • Intended use and target markets
  • The design history file and the risk file
  • Test reports, including accredited lab reports
  • Clinical data or literature, if any
  • Candidate predicate devices, if known

You Get Back

  • Regulatory strategy per market
  • Classification in each market
  • EU technical documentation
  • 510(k) submission content
  • Draft answers to reviewer questions
Questions

Questions Clients Ask

What is a predicate device?

A legally marketed US device that yours is compared with in a 510(k). You show substantial equivalence: the same intended use, and the same technology or differences that raise no new questions of safety and effectiveness.

Does every EU device need a notified body?

No. Most Class I devices are self-declared by the manufacturer. Class I devices that are sterile, have a measuring function or are reusable surgical instruments, and all Class IIa, IIb and III devices, need a notified body.

Can our test reports be used in the US and the EU?

Often, if the lab is accredited and the test follows the version of the standard the regulator recognises. Check the version and the accreditation before testing, not after.