Diagnostic Devices

Devices that measure the patient directly: stethoscopes, screeners and wearable patches. Sensor accuracy, motion artefact, comfort over long wear and the evidence behind the number are the hard parts.

Devices we have built here
Digital stethoscopes, diabetic foot screeners, glaucoma screeners, ECG patches, wearable multivital patches.
The challenge

What Makes These Devices Hard

Accuracy Against a Reference

The number has to agree with a clinical reference, across the population that will use it.

Motion and Skin

Artefact from movement, sweat and skin tone, handled in the sensor and the algorithm.

Power and Wireless

Battery life, charging and a Bluetooth link that holds.

Comfort Over Long Wear

Adhesives and form that stay on for days without harm.

Before you start

Tell Us These First

Useful in a First Enquiry

  • The parameter you measure, and the accuracy you claim
  • Where it is worn, for how long, and by whom
  • The reference method clinicians trust today
  • The battery life, charging and data display you need
  • Any algorithm or dataset you already own
Your path

The Path for a Device Like Yours

  1. Step 1

    Proof of Principle

    Show the sensor picks up the signal on real skin, in motion, across the intended users.

    Proof of principle
  2. Step 2

    Electronics

    Design the analog front end, power and charging for the signal and battery life the claim needs.

    Electronics
  3. Step 3

    Embedded Firmware & BLE

    Write firmware for sampling, artefact flags and a Bluetooth link that recovers from drops.

    Embedded firmware & BLE
  4. Step 4

    Mobile / Web / Cloud App

    Build the app and cloud that show, store and share readings under IEC 62304.

    Mobile / web / cloud app
  5. Step 5

    Verification & Validation

    Run safety, EMC and the accuracy study against the reference method.

    Verification & validation
  6. Step 6

    Pilot & Small-Batch

    Build units for the clinical study and for long-wear trials.

    Pilot & small-batch
Questions

Questions About Diagnostic Devices

Which reference method should our accuracy study use?

The one the relevant standard or clinical practice accepts for that parameter. For automated blood pressure monitors, ISO 81060-2 sets the reference and the study design. Where no standard exists, agree the reference and the acceptance criteria with clinicians and write them into the protocol before the study.

Does our app count as medical device software?

It can. Software that analyses readings to support a diagnosis is usually regulated as part of the device or as a device in its own right, and IEC 62304 then applies. The intended use decides where the line falls.

Which class will our device be?

The class follows the intended use and the classification rules, not the device type. Try the class and route tool.