IF MedTechStart a project

Electronics

Electronics designed to reduce the risk of failing safety and electromagnetic testing. Insulation, leakage and emissions are set against IEC 60601-1 at schematic stage, not after a failed test report.

When to use it

When Electronics Design Is the Right Step

For any device with a battery, a mains supply or a sensor. The architecture should set the insulation before the first schematic, because the layout follows from it.

  • Turn a Breadboard into a Medical Board

    A working breadboard or development-kit prototype that must become a board that can pass IEC 60601-1.

  • Build a Sensing Front End

    Analog front ends for signals such as ECG, temperature or pressure, where noise and patient isolation shape the circuit.

  • Fix a Safety or EMC Problem

    A board that failed, or is likely to fail, electrical safety or EMC testing and needs a redesign.

How it works

How Electronics Design Works

  1. Step 1

    Plan the Isolation

    An architecture with the insulation and the means of protection set first.

  2. Step 2

    Design the Circuits

    Schematics, with parts chosen for supply, temperature and life.

  3. Step 3

    Lay Out and Bring Up

    The board laid out with its spacings, then built and brought up.

  4. Step 4

    Pre-Test

    Safety and EMC checked in-house before the accredited lab.

What you get

What You Bring and What You Get

You Bring

  • What the device measures, powers or controls
  • How it is powered: mains, battery or both
  • Where it is used: hospital, home or in transit
  • Your prototype or reference design, if any
  • Limits on board size and shape

You Get Back

  • Schematics and PCB layout
  • Bill of materials
  • Insulation diagram
  • Bring-up records
  • Pre-compliance results for safety and EMC
Questions

Questions Clients Ask

Why pre-test before the accredited lab?

A pre-compliance check finds the likely failures while the fix is still a small change. Lab time is booked and paid for, and a failed test means a redesign and a second booking.

What does IEC 60601-1-2 cover?

Electromagnetic disturbances: what the device emits, and how well it keeps working when exposed to them. The test levels depend on where the device is used, such as a hospital or a home.

Does a battery-powered device still need isolation?

Often, yes. A charger, a data cable or a connected accessory can bring mains voltage close to the patient. The insulation diagram shows each path and how it is protected.

Have a question about Electronics?

Opens the contact form with this service named. Nothing is sent until you press send.