A laboratory bench with a binocular microscope and other lab instruments.

In-Vitro Diagnostics

Devices that test a sample rather than the patient, from bench analysers to point-of-care assays. Sample handling, reagent stability, calibration and proving analytical performance drive the design.

Devices we have built here
HbA1C analyser, micronutrient screening, haemoglobin quantifier, point-of-care biosensors.
The challenge

What Makes These Devices Hard

Sample Handling

Small volumes, clotting, haemolysis and carry-over all move the result.

Reagent Stability

Shelf life and storage temperature decide the cartridge and the pack.

Calibration

Traceable calibrators and a lot-to-lot plan, set before the first batch.

Analytical Evidence

Precision, accuracy, limits of detection and interference, measured to a written protocol.

Before you start

Tell Us These First

Useful in a First Enquiry

  • The analyte, the sample type and the sample volume
  • The user and setting: laboratory, clinic or home
  • The reference method your result will be compared with
  • The measuring range and precision you need, if known
  • The storage conditions the product must survive
Your path

The Path for a Device Like Yours

  1. Step 1

    Proof of Principle

    Show the chemistry or sensor reads the analyte on real samples before the cartridge is designed.

    Proof of principle
  2. Step 2

    Prototype / MVP

    Build a reader and cartridge that can run a small sample set under controlled conditions.

    Prototype / MVP
  3. Step 3

    Mechanical Engineering

    Design the cartridge, fluid path and pack around the sample volume and the reagent's storage needs.

    Mechanical engineering
  4. Step 4

    Verification & Validation

    Run precision, accuracy, detection limit and interference studies to written protocols.

    Verification & validation
  5. Step 5

    Pilot & Small-Batch

    Build cartridge lots for stability and lot-to-lot studies.

    Pilot & small-batch
  6. Step 6

    India Regulatory Dossier

    Assemble the analytical and clinical evidence for the licence route.

    India regulatory dossier
Questions

Questions About In-Vitro Diagnostic Devices

What is the difference between analytical and clinical performance?

Analytical performance covers how well the test measures the analyte: precision, accuracy, detection limits and interference. Clinical performance covers how well the result identifies the condition in the people it is meant for. Each needs its own study plan.

Which class will our IVD be?

The class follows the intended use and the classification rules for IVDs in each market, not the device type. Try the class and route tool, and read how classification works in India.

Can we use banked samples for our studies?

Often, for analytical work and for some clinical performance studies. ISO 20916 covers how clinical performance studies are planned, including the ethics and consent the specimens need. Confirm the approach with the ethics committee before the study starts.