Getting the device to the patient sterile: the barrier that has to survive the process, the sterilisation route it can take, and the validation that proves it.

When to use it

When Sterile Support Is the Right Step

For devices that reach the patient sterile. Plan it while the design is still open: the sterilisation method limits the materials, and the packaging is part of the device.

  • Choose and Validate the Method

    Ethylene oxide or gamma, chosen to suit the materials and the device, then validated. We coordinate the sterilisation.

  • Sterile Barrier Packaging

    Packaging that keeps the device sterile until use, validated for sealing, transport and shelf life.

  • Labels for the Sterile Field

    Labels that state the sterilisation method and the expiry date, applied to each pack.

How Sterile Support Runs

  1. Step 1

    Review Materials and Design

    Each material checked against the candidate sterilisation methods.

  2. Step 2

    Choose the Method

    Ethylene oxide or gamma, with the reasoning recorded.

  3. Step 3

    Design the Packaging

    The sterile barrier system and its seals, chosen with the method.

  4. Step 4

    Validate

    Sterilisation to ISO 11135 or ISO 11137, and packaging to ISO 11607.

  5. Step 5

    Label

    Labels with the sterilisation method, lot and expiry date.

  6. Step 6

    Release Each Batch

    Each sterilised batch released against its sterilisation records.

What you get

What You Bring and What You Get

You Bring

  • A materials list, with grades
  • Drawings and the bill of materials
  • The intended use, and how the device is presented in use
  • The shelf life you need
  • Any sterilisation or packaging data you already have

You Get Back

  • A recommended sterilisation method, with the reasoning
  • Coordination of ethylene oxide or gamma sterilisation
  • A sterile barrier packaging design
  • Validation records for sterilisation and packaging
  • Labels with sterilisation and expiry information
Questions

Questions Buyers Ask

Should I choose ethylene oxide or gamma?

It depends on the materials, the geometry, the packaging and the volume. Gamma suits many single-use devices made of radiation-stable materials. Ethylene oxide suits materials that radiation would damage, but the gas residues must be removed afterwards.

When should the packaging be designed?

Alongside the device. ISO 11607 treats the sterile barrier system as part of the device, validated for sealing, transport and ageing. A shelf-life claim needs ageing data behind it.

Can I change the method later?

Yes, but it is a design change. Materials, packaging and validation may all need another look, and an approved device may need the regulator to be told.